Mechanical Condition Detector Kit CMVL-3600-IS-K-01


The Marlin Condition Detector Pro IS (MCD) is certified Intrinsically Safe (IS) for Europe and North America. The rugged unit is certified for use in hazardous environment.

 

 

The MCD provides a simple but extremely effective means of checking the health of a machine, measuring vibration and temperature to assess its operating state.

 

By putting MCD into the hand of plant or maintenance personnel, the frequency of checking can be increased, warnings can be received earlier and plant condition experts can be freed to focus only on specific problem areas.

 

Measure Vibration in terms of Velocity and Acceleration Enveloping

Overall Velocity vibration is an excellent measurement parameter for determining rotational and structural problems such as imbalance, misalignment, looseness and stress applied to components. Acceleration Enveloping measures higher frequencies usually associated with bearing problems and gear mesh.

 

Measure Temperature

Temperature is measured by a unique sensing magnet to detect and signal temperatures values outside of the acceptable range. Temperature measurements enhance the "early warning" benefit of the instrument by offering a useful indication of mechanical condition or the load applied to a specific component. As a bearing or lubrication fails, friction causes its temperature to rise.

 

General Alarm Capabilities

The MCD is easily programmed for six alarm settings. When measurements are taken, they are automatically compared to six user-defined settings. The MCD's alarm indicating LED's react appropriately and indicate Green if OK, Yellow for 1st Level Alarm, and Red for 2nd Level Alarm.

 

Intrinsically Safe Approval

Intrinsic Safety (IS): LCIE:

Approved to CENELEC EN50 020, EEX ia Iic T4

CSA: Class I, Division 1, Groups A, B, C, D T3A (USA, Canada)

 

Features:

  • Small and Rugged

  • Overall Vibration in terms of Velocity

  • Acceleration Enveloping

  • Temperature Magnet

  • Includes Vibration Severity Chart

  • Programmable Alarms

  • Visible LED Indicators

    • "Green" OK Indication

    • "Amber" 1st Level Alarm Indication

    • "Red" 2nd Level Alarm Indication

  • Programmable English or Metric

  • Intrinsically Safe: ATEX approved        

Kit includes:

  • MCD

  • Magnetic base with temperature sensor

  • 4" stinger probe

  • Setup key

  • Padded carry case

  • User manual

  • Quick start card

 

Ordering Information:

Buy Now

Part #

Description

Price

SKF-CMVL3600-IS-K-01

Mechanical Condition Detector Kit

$2,895.00

SKF-CMAC3610

Replacement Temperature Magnet

$513.00

 

Specifications:

Measurements

  Velocity Sensor:

Integrated Piezoelectric Accelerometer, Ceramic, Shear Type

  Measurement Range:

Velocity: 0.3 - 55 mm/sec RMS

             0.02 - 3.0 in/sec (Eq. Peak)

Enveloped Acceleration: 0.3 gE - 20.0 gE

Temperature: +32°F to 212°F, 0°C to +100°C

  Frequency Range:

Overall Velocity: 10 Hz - 1 kHz

Enveloped Acceleration: Band 3, 500 Hz to 10 KHz

Display

  Viewing Area:

2.165" x 0.700" (54.99mm x 17.78mm)

Power

  Main Power:

Two (2) 1.5 V alkaline "AA" batteries

  Battery Lifetime:

Thirty (30) hours

  Backup Battery:

One (1) 3 V BR1225 Lithium Ion Battery

  Auto Off:

Two (2) minute countdown on last operation

Physical

  Case:

Water & Dust Resistant, IP65

  Drop Test:

Six (6) feet on multiple axis

  Dimensions:

Length: 7.50" (190.5 mm)

Width: 1.70" (43.2 mm)

Height: 1.63" (41.4 mm)

  Weight:

0.95 lb (431 grams) with battery

1.40 lb (635 grams) with temp. magnet

Environment

  Operating   Temperature:

-4°F to +140°F (-20°C to +60°C) standard locations

-4°F to +104°F (-20°C to +40°C) hazardous locations

  Storage Temperature:

-34°F to 158°F (-37°C to +70°C)

  Humidity:

5-95% noncondensing