TI-25DL Series Data Logging
Thickness Gauges |
|
The
new CHECK-LINE TI-25DL accurately measures wall thickness and the extent of
corrosion of all metals, ceramics, glass and most rigid plastics -
from only one side!
The
TI-25DL incorporates a built-in memory for 1000 data points that can be
separated into 10 separate "batches." The stored data can be downloaded to a
serial printer or a personal computer. A Windows compatible data transfer
program is supplied at no additional cost.
The gauge can be used in a Single Thickness Reading mode or in two
alternative modes, the Scan mode and the and the Differential mode. The Scan
modes permits the user to "drag" the probe over a large measuring area where
the minimum thickness encountered during the scan will be displayed. The
Differential mode displays the difference ("+" or "-") from a set "nominal"
value. |
 |
|
 |
The
TI-25DL is supplied as a complete kit with the gauge, probe, 4 oz. bottle of
coupling fluid, 2 AA batteries, NIST Calibration Certificate, data transfer
software, serial output cable and Operating Instruction Manual - all in a
foam-fitted carrying case.
Features:
-
Resolution of 0.001 inch
(0.01 mm)
-
Selectable units of inch
or mm
-
Large, backlit LCD
display retains last reading
-
Memory for 1000 data
points in up to 10 batches
-
RS-232C Serial output for
downloading stored data to a printer or computer
-
Special-purpose probes
are offered for a variety of applications
-
Windows compatible data
transfer program supplied at no additional cost.
|
Ordering Information
Accessories
Specifications:
|
Range* |
0.025-6.00" (0.60-150.0 mm) |
|
Resolution |
.001"
(0.01 mm) |
|
Display |
4½
- Digit, 0.5" Backlit LCD |
|
Velocity Range |
6,500-33,000 ft./sec (2000-10,000 m/sec.) |
|
Probe |
7.5
MHz, 0.25" Diameter (6.35 mm) with rubber molded grip. |
|
Probe Wearface |
PEEK
(Polyethlethylketone) |
|
Cable |
4 ft.
(1.2 m) waterproof cable with non-polarized, quick-disconnect connectors.
Optional lengths up to 100 ft. (30 m). |
|
Test Block |
0.250" (6.35 mm) steel plate built in to the front of housing. |
|
Serial Output |
RS-232C (8, N, 1, user-set baud rate) |
|
Temp. Limits |
Ambient: -20 to 120° F (-30 to 50° C)
Material: --ll0
to 200° F (-20 to 100° C)
Special high temperature probes are optionally available. |
|
Battery Type |
Two
AA batteries |
|
Battery Life |
200
hours |
|
Weight |
7
ounces (196 g) |
|
Size |
3.25
x 6.00 x 1.35"
(82.5 x 152.4 x 34.3 mm) |
|
Warranty |
Gauge: 5 years
Probe: 90 days |
|
 |
Minimum radius for convex surfaces |
0.5"
(12.7 MM) |
|
Minimum radius for concave surfaces |
2.5"
(63.5 mm) |
|
 |
Minimum headroom |
1.3"
(33.0 mm) |
|
 |
Minimum sample diameter |
0.5"
(12.7 mm) |
|