Imbalance causes high levels of mechanical stress and
vibration, when imparted to your bearings, will cause a reduction in the
normal bearing life. It is essential for the health of your rotating
machinery to be balanced correctly to minimize any resultant damage caused
by the excessive stressed of vibration.
Not sure
what level of unbalance in acceptable?
Built into the VB-1000B firmware id the ISO 1940
standard. This internationally recognized standard is the most
widely-followed balancing guideline in the industry today. By simply
entering a few basic parameters, the VB-1000B will calculate the
acceptable level of residual imbalance for you, thus giving you an
acceptable tolerance to work toward. The VB-1000B offers the perfect
portable solution to your balancing problems.
Other Calculations Available:
-
Trial Weight - Automatically suggested mass value for
increased accuracy of balancing set up
-
Split Weights - Allows a correction weight normally
specified at a particular angle to be split and applied at alternative
angles
-
Combine Weights - Calculates combined mass for a
particular correction angle
-
Change Radius - Calculates the change required for
the correction of mass at a given radius
Set Up - The VB-1000B set up is minimal, quick and easy.
Only a few calibration runs are required with, or without, removing your
trial weight.
Memory - The VB-1000B stores your previous balance data.
No need to waste valuable time performing calibration runs on repetitive
or routine balance jobs.
Balance - Imbalance is computed quickly and the display
indicated the angular position for weight correction.
Reporting - Balancing reports, including Customer and
Machine details can be printed directly from the VB-1000B to a thermal
printer for the spot reports. |